> -----Original Message-----
> From: Gregory Etelson <[email protected]>
> Sent: Thursday, November 11, 2021 18:16
> To: [email protected]; Gregory Etelson <[email protected]>; Slava Ovsiienko
> <[email protected]>
> Cc: [email protected]; Matan Azrad <[email protected]>
> Subject: [PATCH] net/mlx5: fix integrity conversion scheme
> 
> RTE flow integrity API provides top-level packet validations.
> RTE integrity bits are not always translated one-to-one to hardware integrity
> bits.
> For example RTE l3_ok and l4_ok integrity bits require 2 hardware integrity
> bits each.
> 
> The patch fixes RTE l3_ok and l4_ok bits translation to match
> ConnectX-6 hardware.
> 
> Cc: [email protected]
> 
> Fixes: 79f8952783d0 ("net/mlx5: support integrity flow item")
> 
> Signed-off-by: Gregory Etelson <[email protected]>
Acked-by: Viacheslav Ovsiienko <[email protected]>

Reply via email to