The PCI domain in Azure maybe 32 bits. When device is passed through the domain is synthesize from the internal GUID. The code that parses for PCI address in Mellanox drivers needs to use wider scanf format.
Signed-off-by: Stephen Hemminger <[email protected]> --- v3 - add MLX4 drivers/net/mlx4/mlx4.c | 2 +- drivers/net/mlx5/mlx5_ethdev.c | 2 +- 2 files changed, 2 insertions(+), 2 deletions(-) diff --git a/drivers/net/mlx4/mlx4.c b/drivers/net/mlx4/mlx4.c index 16cafae7d741..902a669c923a 100644 --- a/drivers/net/mlx4/mlx4.c +++ b/drivers/net/mlx4/mlx4.c @@ -5239,7 +5239,7 @@ mlx4_ibv_device_to_pci_addr(const struct ibv_device *device, /* Extract information. */ if (sscanf(line, "PCI_SLOT_NAME=" - "%" SCNx16 ":%" SCNx8 ":%" SCNx8 ".%" SCNx8 "\n", + "%" SCNx32 ":%" SCNx8 ":%" SCNx8 ".%" SCNx8 "\n", &pci_addr->domain, &pci_addr->bus, &pci_addr->devid, diff --git a/drivers/net/mlx5/mlx5_ethdev.c b/drivers/net/mlx5/mlx5_ethdev.c index 96bccd5fd201..039335e2e470 100644 --- a/drivers/net/mlx5/mlx5_ethdev.c +++ b/drivers/net/mlx5/mlx5_ethdev.c @@ -1185,7 +1185,7 @@ mlx5_ibv_device_to_pci_addr(const struct ibv_device *device, /* Extract information. */ if (sscanf(line, "PCI_SLOT_NAME=" - "%" SCNx16 ":%" SCNx8 ":%" SCNx8 ".%" SCNx8 "\n", + "%" SCNx32 ":%" SCNx8 ":%" SCNx8 ".%" SCNx8 "\n", &pci_addr->domain, &pci_addr->bus, &pci_addr->devid, -- 2.11.0