[ https://issues.apache.org/jira/browse/EAGLE-719?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel ]
Michael Wu resolved EAGLE-719. ------------------------------ Resolution: Fixed > configuration bug in applications > --------------------------------- > > Key: EAGLE-719 > URL: https://issues.apache.org/jira/browse/EAGLE-719 > Project: Eagle > Issue Type: Bug > Affects Versions: v0.5.0 > Reporter: wujinhu > Assignee: Michael Wu > Fix For: v0.5.0 > > > In > eagle-hadoop-queue/eagle-jpm-mr-history/eagle-jpm-mr-running/eagle-jpm-spark-history/eagle-jpm-aggregation > applications, there is an xxxAppConfig class in each application. But they > have a static member like manager, which could not initialize twice > -------------------------------------------------------------------- > public static xxxxConfig getInstance(Config config) { > if (config != null && manager.config == null) { > manager.init(config); > } > return manager; > } > -------------------------------------------------------------------- > But we have many sites in production, and will call method getInstance many > times. So it will cause we may get the configuration of first site for > remaining sites. -- This message was sent by Atlassian JIRA (v6.3.4#6332)