Hi I can’t see the screenshots you’ve included below, but my understanding is that the trapdoor properties are ones that can only be modified BEFORE you start Fineract for the first time.
Once you’ve started the application for the first time, the configured values have been used and cannot be updated (as that would require recalculating all values stored so far). This seems to be aligned with what’s described in the Mifos documentation (eg https://mifosforge.jira.com/wiki/spaces/MIFOS/pages/74186883/Configuration+Guide <https://mifosforge.jira.com/wiki/spaces/MIFOS/pages/74186883/Configuration+Guide>): " About the One-Time Settings When Mifos runs for the first time, it writes values to its database. Although many of these values can be changed later, some cannot. Specifically, the values from the Chart of Accounts can only be written to the database once. Similarly, TRAPDOOR properties in the application configuration file can only be assigned non-default values once, before you run Mifos for the first time. After that point, a TRAPDOOR property value can only be changed to its default setting. " Regards Petri > On 1 Apr 2022, at 19:15, sif...@skyburgsystems.org wrote: > > Hey all, > > In the Global configurations under rounding mode you have the option to > change the rounding mode from 1 to 6 depending on how you want your Figures > to round off. > > > > Currently it produces this error when you try and change the value to > anything apart from 6. So if you want to round down for example it fails. Is > this a bug or is there a way to get round this Trap door? > > > > > > This email has been scanned by BullGuard antivirus protection. > For more info visit www.bullguard.com > <http://www.bullguard.com/tracking.aspx?affiliate=bullguard&buyaffiliate=smtp&url=/>