Aljoscha Krettek created FLINK-2891:
---------------------------------------

             Summary: Key for Keyed State is not set upon Window Evaluation
                 Key: FLINK-2891
                 URL: https://issues.apache.org/jira/browse/FLINK-2891
             Project: Flink
          Issue Type: Sub-task
          Components: Streaming
    Affects Versions: 0.10
            Reporter: Aljoscha Krettek
            Assignee: Aljoscha Krettek
            Priority: Blocker


In both the aligned and the general-purpose windows the key for the keyed 
operator state is not set when evaluating the windows. This silently leads to 
incorrect results.



--
This message was sent by Atlassian JIRA
(v6.3.4#6332)

Reply via email to