Yun Tang created FLINK-13910:
--------------------------------
Summary: Many serializable classes have no explicit
'serialVersionUID'
Key: FLINK-13910
URL: https://issues.apache.org/jira/browse/FLINK-13910
Project: Flink
Issue Type: Bug
Reporter: Yun Tang
Attachments: SerializableNoSerialVersionUIDField
Currently, many serializable classes in Flink have no explicit
'serialVersionUID'. As [official
doc|https://flink.apache.org/contributing/code-style-and-quality-java.html#java-serialization]
said, {{Serializable classes must define a Serial Version UID}}.
No 'serialVersionUID' would cause compatibility problem. Take
{{TwoPhaseCommitSinkFunction}} for example, since no explicit
'serialVersionUID' defined, after
[FLINK-10455|https://github.com/apache/flink/commit/489be82a6d93057ed4a3f9bf38ef50d01d11d96b]
introduced, its default 'serialVersionUID' has changed from
"4584405056408828651" to "4064406918549730832". In other words, if we submit a
job from Flink-1.6.3 local home to remote Flink-1.6.2 cluster with the usage of
{{TwoPhaseCommitSinkFunction}}, we would get exception like:
{code:java}
org.apache.flink.streaming.runtime.tasks.StreamTaskException: Cannot
instantiate user function.
at
org.apache.flink.streaming.api.graph.StreamConfig.getStreamOperator(StreamConfig.java:239)
at
org.apache.flink.streaming.runtime.tasks.OperatorChain.<init>(OperatorChain.java:104)
at
org.apache.flink.streaming.runtime.tasks.StreamTask.invoke(StreamTask.java:267)
at org.apache.flink.runtime.taskmanager.Task.run(Task.java:711)
at java.lang.Thread.run(Thread.java:748)
Caused by: java.io.InvalidClassException:
org.apache.flink.streaming.api.functions.sink.TwoPhaseCommitSinkFunction; local
class incompatible: stream classdesc serialVersionUID = 4584405056408828651,
local class serialVersionUID = 4064406918549730832
at java.io.ObjectStreamClass.initNonProxy(ObjectStreamClass.java:699)
at
java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1885)
at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1751)
at
java.io.ObjectInputStream.readNonProxyDesc(ObjectInputStream.java:1885)
at java.io.ObjectInputStream.readClassDesc(ObjectInputStream.java:1751)
at
java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:2042)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1573)
at
java.io.ObjectInputStream.defaultReadFields(ObjectInputStream.java:2287)
at java.io.ObjectInputStream.readSerialData(ObjectInputStream.java:2211)
at
java.io.ObjectInputStream.readOrdinaryObject(ObjectInputStream.java:2069)
at java.io.ObjectInputStream.readObject0(ObjectInputStream.java:1573)
at java.io.ObjectInputStream.readObject(ObjectInputStream.java:431)
at
org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:537)
at
org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:524)
at
org.apache.flink.util.InstantiationUtil.deserializeObject(InstantiationUtil.java:512)
at
org.apache.flink.util.InstantiationUtil.readObjectFromConfig(InstantiationUtil.java:473)
at
org.apache.flink.streaming.api.graph.StreamConfig.getStreamOperator(StreamConfig.java:224)
... 4 more
{code}
Similar problems existed in
{{org.apache.flink.streaming.api.operators.SimpleOperatorFactory}} which has
different 'serialVersionUID' from release-1.9 and current master branch.
IMO, we might have two options to fix this bug:
# Add explicit serialVersionUID for those classes which is identical to latest
Flink-1.9.0 release code.
# Use similar mechanism like {{FailureTolerantObjectInputStream}} in
{{InstantiationUtil}} to ignore serialVersionUID mismatch.
I have collected all production classes without serialVersionUID from latest
master branch in the attachment, which counts to 639 classes.
--
This message was sent by Atlassian Jira