Weijie Guo created FLINK-29034:
----------------------------------

             Summary: HYBRID_FULL result partition type is not yet reConsumable
                 Key: FLINK-29034
                 URL: https://issues.apache.org/jira/browse/FLINK-29034
             Project: Flink
          Issue Type: Bug
          Components: Runtime / Coordination
    Affects Versions: 1.16.0
            Reporter: Weijie Guo
             Fix For: 1.16.0


HYBRID_FULL partitions can be consumed repeatedly, but it does not support 
concurrent consumption. So re-consumable is false, but double calculation can 
be avoided during failover. If we regard it as re-consumable, there will be 
problems when the partition is reused. Therefore, we temporarily set this field 
false, and reset it to true when HsResultPartition supports downstream 
concurrent consumption of multiple identical subpartitions.



--