Jiale Tan created FLINK-29610:
---------------------------------
Summary: Infinite timeout is used in SavepointHandlers calls to
RestfulGateway
Key: FLINK-29610
URL: https://issues.apache.org/jira/browse/FLINK-29610
Project: Flink
Issue Type: Bug
Components: Runtime / REST
Reporter: Jiale Tan
In {{{}SavepointHandlers{}}}, both
{{[StopWithSavepointHandler|https://github.com/apache/flink/blob/cd8ea8d5b207569f68acc5a3c8db95cd2ca47ba6/flink-runtime/src/main/java/org/apache/flink/runtime/rest/handler/job/savepoints/SavepointHandlers.java#L214]}}
and
{{[SavepointTriggerHandler|https://github.com/apache/flink/blob/cd8ea8d5b207569f68acc5a3c8db95cd2ca47ba6/flink-runtime/src/main/java/org/apache/flink/runtime/rest/handler/job/savepoints/SavepointHandlers.java#L258]}}
are calling {{RestfulGateway}} with {{RpcUtils.INF_TIMEOUT}}
As pointed out in
[this|https://github.com/apache/flink/pull/20852#discussion_r992218970]
discussion, we will need to either figure out why {{RpcUtils.INF_TIMEOUT}} is
used, or remove it if there is no strong reason to use it.
--
This message was sent by Atlassian Jira
(v8.20.10#820010)