Qiu created FLINK-35929: --------------------------- Summary: In flink insert mode, it supports modifying the parallelism of jdbc sink when the parallelism of source and sink is the same. Key: FLINK-35929 URL: https://issues.apache.org/jira/browse/FLINK-35929 Project: Flink Issue Type: Improvement Components: Connectors / JDBC Affects Versions: jdbc-3.1.2 Reporter: Qiu Attachments: image-2024-07-30-19-57-45-033.png, image-2024-07-30-19-57-50-868.png
In insert mode, when the source and sink parallelism are consistent, if you reduce or increase the jdbc sink parallelism, the SQL verification will report an error. The following is the error message. configured sink parallelism is: 8, while the input parallelism is: -1. Since configured parallelism is different from input parallelism and the changelog mode contains [INSERT,UPDATE_AFTER,DELETE], which is not INSERT_ONLY mode, primary key is required but no primary key is found! {code:java} //代码占位符 module: flink-connector-jdbc class: org.apache.flink.connector.jdbc.table.JdbcDynamicTableSink public ChangelogMode getChangelogMode(ChangelogMode requestedMode) { validatePrimaryKey(requestedMode); ChangelogMode.Builder changelogModeBuilder = ChangelogMode.newBuilder() .addContainedKind(RowKind.INSERT); if (tableSchema.getPrimaryKey().isPresent()) { changelogModeBuilder .addContainedKind(RowKind.UPDATE_AFTER) .addContainedKind(RowKind.DELETE); } return changelogModeBuilder.build(); } {code} -- This message was sent by Atlassian Jira (v8.20.10#820010)