Sylwester Lachiewicz created FLINK-41515:
--------------------------------------------
Summary: KafkaSinkE2ECase restartFromSavepoint fails before the
savepoint with POOLING and AT_LEAST_ONCE
Key: FLINK-41515
URL: https://issues.apache.org/jira/browse/FLINK-41515
Project: Flink
Issue Type: Bug
Components: Connectors / Kafka
Affects Versions: kafka-5.1.0
Reporter: Sylwester Lachiewicz
{{KafkaSinkE2ECase}} fails intermittently in
{{SinkTestSuiteBase.restartFromSavepoint}} while it stops the first job with a
savepoint, before any restore. Both failures so far use {{ExternalContext:
[POOLING], Semantic: [AT_LEAST_ONCE]}}.
||Test||Where||Result||Run||
|{{testScaleUp}}|{{SinkTestSuiteBase.java:288}},
{{stopWithSavepoint(...).get(30, TimeUnit.SECONDS)}}|{{TimeoutException}} after
33.7 s|[Flink 2.2.1, JDK
11|https://github.com/apache/flink-connector-kafka/actions/runs/39342878234/job/118368418382],
2026-10-20|
|{{testScaleDown}}|{{SinkTestSuiteBase.java:280}} ->
{{waitExpectedSizeData:647}}|failure after 60.8 s|[Flink 2.2.1, JDK
21|https://github.com/apache/flink-connector-kafka/actions/runs/43735631597/job/132877501370],
2026-11-15|
The other jobs of the same commits passed, or were cancelled by fail-fast.
Neither run's PR touches the E2E module ([PR
#314|https://github.com/apache/flink-connector-kafka/pull/314], [PR
#288|https://github.com/apache/flink-connector-kafka/pull/288]), and
{{AT_LEAST_ONCE}} writes without transactions.
What the logs show:
* The job logs contain no output from the Flink JobManager or TaskManager
containers, and the runs uploaded no artifacts, so the cause can't be read from
CI.
* In the 2026-10-20 run, the test JVM's admin clients failed to connect to the
broker's mapped port ({{localhost:32869}}) 634 times between 00:06:06 and the
failure at 00:07:20, while other tests in the class were still passing. The JDK
17 job of the same run logs 29 such warnings, all at teardown.
Earlier {{KafkaSinkE2ECase}} failures,
[FLINK-26921|https://issues.apache.org/jira/browse/FLINK-26921] and
[FLINK-30911|https://issues.apache.org/jira/browse/FLINK-30911], were closed as
Cannot Reproduce. Collecting the Flink container logs when an E2E test fails
would make the next occurrence diagnosable.
--
This message was sent by Atlassian Jira
(v10.3.26#10030026)