Hi Yanquan, Thanks for reviewing the latest design doc and POC. Yes, you are right. The current PoC is using the max-records-per-second for the initial limit. The initial RecordsnitialRecordsPerSecond in `RateLimiterStrategy.dynamic(initialRecordsPerSecond)` is not actually used, and the max-records-per-second is not used as the upper bound in code path other than the rate adjustment. I did two changes
1. initialRecordsPerSecond provided to `RateLimiterStrategy.dynamic(initialRecordsPerSecond)` is used for initial limit with the upper bound of max-records-per-second. 2. Adjust the propagation of target rate limit strategy like below - propagates the target rate limit restored from state immediately if the job recovered from failure - propagates the target rate limit only after the total throughput is observed for fresh jobs initially. https://github.com/apache/flink/pull/29627 In this way, we may make the limit adjustment consistently according to user configuration and also runtime expectation. Best Regards Peter Huang On Wed, Nov 25, 2026 at 12:29 AM Yanquan Lv via dev <[email protected]> wrote: > Hi Peter, > > Thanks for updating this FLIP. I re-read it carefully and noticed a > potential issue — since my analysis is based only on the design document (I > could not find an implementation to verify it against), could you please > help confirm whether this matches the intended behavior, or whether I am > misreading anything? > > The initial rate configured by the connector through > `RateLimiterStrategy.dynamic(initialRecordsPerSecond)` never reaches the > coordinator: `DynamicRateLimitParams` has no `initial` field; the reader's > throughput is reported via `ReportedThroughputEvent` only after a > checkpoint completes, and the first rate adjustment also runs after > checkpoint completion. As specified, "Its first checkpoint broadcasts the > max", with a fallback to the previous target when no throughput has been > reported — and the only initial rate value available in the params is > `max-records-per-second`. > > As currently specified, the first checkpoint of a fresh job broadcasts > `max-records-per-second` (default `Double.MAX_VALUE`). The reader then > applies `max / parallelism`, the limiter effectively stops throttling, and > throughput jumps to the data supply rate — the connector-configured 5,000 > survives for exactly one checkpoint interval, without any warning or > indication. > > Best, > Yanquan > > Zhanghao Chen <[email protected]> 于2026年10月8日周四 13:38写道: > > > Hi Peter, > > > > Thanks for putting this together. Dynamic rate limiting is a useful > > feature in production. The overall architecture LGTM and can serve as a > > powerful tool for implementing custom strategies (e.g. detecting > throttling > > on the source datastore). I'm not too sure about the effectiveness and > the > > generality of the algorithm proposed though. Could you share more > > production stats in your use case? I also suggest starting by just > > providing a programming interface and an experimental implementation > first > > and avoid introducing a set of new options, as these options might be > more > > suitable as a per-source/table option and we'll need more time to see if > > the default algorithm is stable. > > > > Best, > > Zhanghao Chen > > ________________________________ > > From: Peter Huang <[email protected]> > > Sent: Wednesday, October 7, 2026 2:36 > > To: [email protected] <[email protected]> > > Subject: Re: [Discuss] FLIP-XXX: Dynamic Rate Limiting for FLIP-27 Source > > > > Hi David, > > > > Thanks for this valuable feedback. I totally agree that Unequal split > > assignment and Partition skew should be considered in the default > > algorithm. > > As you suggested, weighting the allocation proportionally based on each > > subtask's reported throughput (or active split count) is the feasible > > default solution. > > To support data patterns of different sources, we may expose an interface > > for users to define the customized algorithm for their needs. > > Will update the proposal accordingly by today. > > > > > > > > Best Regards > > Peter Huang > > > > On Tue, Oct 6, 2026 at 10:08 AM David Radley <[email protected]> > > wrote: > > > > > Hi Peter, > > > Thanks for putting together this FLIP proposal. I think this is a > > > pragmatic way to address this issue. > > > > > > One question / observation regarding rate distribution across subtasks: > > > > > > In the proposal, the global target rate is divided evenly across > subtasks > > > (targetRate / parallelism). However, it might be that : > > > > > > * > > > Unequal split assignment: The number of splits/partitions may not > divide > > > evenly across subtasks (e.g., 10 partitions across 4 subtasks). > > > > > > -Partition skew: Some partitions or splits naturally produce > > > significantly higher traffic than others. > > > > > > Under an equal division strategy, subtasks handling more splits (or hot > > > partitions) will be capped prematurely, while subtasks with fewer or > idle > > > splits will underutilize their quota, pulling total throughput below > the > > > target rate. > > > > > > Given that subtasks already report their individual numRecordsOutRate > > back > > > to the SourceCoordinator via ReportedThroughputEvent, have you > > considered: > > > > > > > > > * > > > weighting the allocation proportionally based on each subtask's > reported > > > throughput (or active split count) > > > > > > or > > > > > > * > > > providing an different strategy for how the target rate is distributed > > > across subtasks? > > > > > > Kind regards, David, > > > > > > From: Peter Huang <[email protected]> > > > Date: Wednesday, 30 September 2026 at 19:37 > > > To: dev <[email protected]>; Peter Huang < > [email protected]> > > > Subject: [EXTERNAL] [Discuss] FLIP-XXX: Dynamic Rate Limiting for > FLIP-27 > > > Source > > > > > > Hi Everyone, > > > > > > I would like to start a discussion on FLIP-XXX: Dynamic Rate Limiting > for > > > FLIP-27 Source [1]. > > > > > > Flink's FLIP-27 Source API already supports rate limiting (RateLimiter > / > > > RateLimiterStrategy / RateLimitedSourceReader in flink-core), but the > > limit > > > is static: it's fixed once at source construction time and has no > > > visibility into how the job is actually running. > > > > > > Two pain points observed in this static rate limit feature. > > > > > > 1. > > > > > > It is hard to set up a static limit for different scenarios, for > > > example, periodical traffic peak, regional failover situation, and > > etc. > > > 2. > > > > > > For pipelines that throughput is bounded by in process RPC or > > downstream > > > service. Users prefer to slow down the process rather than impact > > these > > > services or job failure due to checkpoint timeout. > > > > > > The proposal aims to add features below to improve the resiliency of > > Flink > > > application with adjustable ratelimit with the feedback loop from > > > checkpoint time: > > > > > > > > > 1. > > > > > > Add a dynamic rate limit to the Source interface that can adjust > > itself > > > automatically, using the historical checkpoint completion time > tracked > > > by the SourceCoordinator as the feedback signal (checkpoints getting > > > slower → back off; checkpoints healthy → ramp back up). > > > 2. > > > > > > Expose the tuning knobs as standard Flink ConfigOptions instead of a > > > hand-rolled parameters object, so the feature is configurable the > same > > > way > > > as any other Flink job setting. > > > 3. > > > > > > Base the actual rate adjustment on the source operator's current > > > observed throughput, not on the previously-broadcast target rate, > so a > > > throttle/ramp decision takes effect immediately instead of > compounding > > > off > > > a stale number. > > > > > > > > > > > > > > > Looking forward to your feedback! > > > > > > > > > Best Regards > > > Peter Huang > > > > > > [1] > > > > > > > > > https://docs.google.com/document/d/1oOUBY6cbLnbvA3Xs9Hm8irvxStPHy5jIEjFec_46rNg/edit?tab=t.0#heading=h.exegx0l01gnh > > > > > > Unless otherwise stated above: > > > > > > IBM United Kingdom Limited > > > Registered in England and Wales with number 741598 > > > Registered office: Building C, IBM Hursley Office, Hursley Park Road, > > > Winchester, Hampshire SO21 2JN > > > > > >