https://issues.apache.org/jira/browse/FLUME-1479?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=13437620#comment-13437620
]
Denny Ye commented on FLUME-1479:
---------------------------------
It's the first time I know the comment 'Multiple sinks can talk to the same
channel. That is a part of the design.'. All of changes of this patch is based
on the standpoint 'single Sink can only talk to unified Channel.'. It might be
my mistake of from Flume documentation for this character.
> Multiple Sinks can connect to single Channel
> --------------------------------------------
>
> Key: FLUME-1479
> URL: https://issues.apache.org/jira/browse/FLUME-1479
> Project: Flume
> Issue Type: Bug
> Components: Configuration
> Affects Versions: v1.2.0
> Reporter: Denny Ye
> Assignee: Denny Ye
> Fix For: v1.3.0
>
> Attachments: FLUME-1479.patch
>
>
> If we has one Channel (mc) and two Sinks (hsa, hsb), then they may be
> connected with each other with configuration example
> {quote}
> agent.sinks.hsa.channel = mc
> agent.sinks.hsb.channel = mc
> {quote}
> It means that there have multiple Sinks can connect to single Channel.
> Normally, one Sink only can connect to unified Channel
--
This message is automatically generated by JIRA.