Vladimir Ozerov created IGNITE-9347:
---------------------------------------
Summary: Attempt to start a dynamic cache with invalid
configuration leads to exchange worker death
Key: IGNITE-9347
URL: https://issues.apache.org/jira/browse/IGNITE-9347
Project: Ignite
Issue Type: Bug
Components: cache
Affects Versions: 2.6, 2.5
Reporter: Vladimir Ozerov
Fix For: 2.7
Reproducer - {{SqlIllegalSchemaSelfTest}}. Technically, this test pass. But
note the following:
1) See logs of {{*Dynamic}} tests - instead of normal stop, node gets killed by
failure detector:
{code:java}
[2018-08-22
14:20:39,777][ERROR][exchange-worker-#77%query.SqlIllegalSchemaSelfTest%][IgniteTestResources]
Critical system error detected. Will be handled accordingly to configured
handler [hnd=class o.a.i.failure.NoOpFailureHandler, failureCtx=FailureContext
[type=SYSTEM_WORKER_TERMINATION, err=java.lang.AssertionError: stopping=true,
groupName=null, caches=[]]]
java.lang.AssertionError: stopping=true, groupName=null, caches=[]
at
org.apache.ignite.internal.processors.cache.CacheGroupContext.singleCacheContext(CacheGroupContext.java:371){code}
2) Similar behavior is observed if one tries to start caches with invalid
configuration twice. Pick any {{*Dynamic}} test and just copy/paste
{{GridTestUtils.assertThrows}} logic one after another. Expected - two expected
exceptions, actual - node is killed.
--
This message was sent by Atlassian JIRA
(v7.6.3#76005)