chin created IGNITE-12074: ----------------------------- Summary: setFailureDetectionTimeout causes Critical system error detected in log Key: IGNITE-12074 URL: https://issues.apache.org/jira/browse/IGNITE-12074 Project: Ignite Issue Type: Bug Reporter: chin
If I do setFailureDetectionTimeout(4000); then the log is filled with this {noformat} 2019-08-13T15:59:17.792 SEVERE org.apache.ignite.internal.processors.failure.FailureProcessor.process DataGrid :: Critical system error detected. Will be handled accordingly to configured handler [hnd=StopNodeFailureHandler [super=AbstractFailureHandler [ignoredFailureTypes=[SYSTEM_WORKER_BLOCKED]]], failureCtx=FailureContext [type=SYSTEM_WORKER_BLOCKED, err=class o.a.i.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=GwClientDGConnectionService-1565726338232--1-[abc], finished=false, heartbeatTs=1565726352914]]] class org.apache.ignite.IgniteException: GridWorker [name=partition-exchanger, igniteInstanceName=GwClientDGConnectionService-1565726338232--1-[abc], finished=false, heartbeatTs=1565726352914] at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1831) at org.apache.ignite.internal.IgnitionEx$IgniteNamedInstance$2.apply(IgnitionEx.java:1826) at org.apache.ignite.internal.worker.WorkersRegistry.onIdle(WorkersRegistry.java:233) at org.apache.ignite.internal.util.worker.GridWorker.onIdle(GridWorker.java:297) at org.apache.ignite.internal.processors.timeout.GridTimeoutProcessor$TimeoutWorker.body(GridTimeoutProcessor.java:221) at org.apache.ignite.internal.util.worker.GridWorker.run(GridWorker.java:120) at java.lang.Thread.run(Thread.java:748) 2019-08-13T15:59:17.792 WARNING org.apache.ignite.internal.util.IgniteUtils.dumpThreads DataGrid :: No deadlocked threads detected.{noformat} The nodes are all on my local machine so there's no network latency or anything. Despite the logs, there doesn't seem to be any issue with the app running. -- This message was sent by Atlassian JIRA (v7.6.14#76016)