Thanks Denis!

This feature significantly simplifies failure detection configuration in
Ignite - just one configuration flag now vs. don't even remember how many.

Have you run a yardstick test on Amazon EC2 with this new configuration
flag? If we kill a node in the middle, then drop should be insignificant.

Also, I want to note your excellent handling of Jira communication. The
ticket has been thoroughly updated every step of the way.

D.

On Fri, Jul 24, 2015 at 5:37 AM, Denis Magda <[email protected]> wrote:

> Igniters,
>
> Have just back merged the changes into the main development branch. Thanks
> Yakov and Dmitriy for spending your time on review!
>
> From now it’s possible to detect failures at cluster nodes'
> discovery/communication/network levels by altering a single parameter -
> IgniteConfiguration.failureDetectionTimeout.
>
> By setting the failure detection timeout for a server node it will be
> possible to detect failed nodes in a cluster topology during the time equal
> to timeout's value and switch to/keep working with only alive nodes.
> By setting the timeout for a client node will let us to detect failures
> between the client and its router node (a server node that is a part of a
> topology).
>
> In addition, bunch of other improvements and simplifications were done at
> the level of TcpDiscoverySpi and TcpCommunicationSpi. Changes are
> aggregated here:
> https://issues.apache.org/jira/browse/IGNITE-752 <
> https://issues.apache.org/jira/browse/IGNITE-752>
>
> —
> Denis

Reply via email to