Hi all, I just wanted to inform you that I asked the provider of the Policeman Jenkins Server to replace the first of two NVMe SSDs, because it failed with fatal warnings due to too many writes and no more spare sectors:
> root@serv1 ~ # nvme smart-log /dev/nvme0 > Smart Log for NVME device:nvme0 namespace-id:ffffffff > critical_warning : 0x1 > temperature : 76 C > available_spare : 2% > available_spare_threshold : 10% > percentage_used : 67% > data_units_read : 62,129,054 > data_units_written : 648,788,135 > host_read_commands : 6,426,997,226 > host_write_commands : 5,582,107,803 > controller_busy_time : 86,754 > power_cycles : 21 > power_on_hours : 20,252 > unsafe_shutdowns : 16 > media_errors : 0 > num_err_log_entries : 0 > Warning Temperature Time : 7855 > Critical Composite Temperature Time : 0 > Temperature Sensor 1 : 76 C > Thermal Management T1 Trans Count : 0 > Thermal Management T2 Trans Count : 0 > Thermal Management T1 Total Time : 0 > Thermal Management T2 Total Time : 0 The second one looks a bit better, but will be changed later, too. I have no idea what a data unit is (512 bytes, 2048 bytes,... - I think one LBA). So we are really shredding SSDs with Lucene tests 😊 Uwe P.S.: The replacement is currently going on... ----- Uwe Schindler Achterdiek 19, D-28357 Bremen https://www.thetaphi.de eMail: [email protected] --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]