LE secure authentication is working now.
The issue was, for LE secure connection MSYS_1_BLOCK_SIZE we need to
increase to 292 at least.

On Tue, May 14, 2024 at 10:21 AM Jain A D <jain...@trenser.com> wrote:

> Hi all
>
> I'm trying to enable LE secure pairing and bonding for Nimble. Doing this
> by using nRF Connect desktop application.
> Pairing and bonding is working if we try in *legacy *(passkey method). If
> we try the same in LE secure, the nRF connect application shows error* 
> Authentication
> failed with status BLE_GAP_SEC_STATUS_PDU_INVALID*.
> Please help me to find out the possible solution for this issue.
>
> Regards
> Jain
>

Reply via email to