https://issues.apache.org/jira/browse/ODE-829?page=com.atlassian.jira.plugin.system.issuetabpanels:all-tabpanel
]
Sathwik Bantwal Premakumar updated ODE-829:
-------------------------------------------
Fix Version/s: 1.3.7
> if process is retired the inflight instances dont work
> ------------------------------------------------------
>
> Key: ODE-829
> URL: https://issues.apache.org/jira/browse/ODE-829
> Project: ODE
> Issue Type: Bug
> Components: BPEL Runtime
> Reporter: Anurag Aggarwal
> Fix For: 1.3.7, 1.4
>
> Attachments: patch.829, patch.829.1
>
>
> steps to reproduce
> 1. deploy version of process with two receives
> 2. create instance by sending message for first receive, but not complete
> instance
> 3. deploy newer version of the process with partnerlink removed/renamed
> 4. send second message for receive for the instance created in 2
> we get mex timeout because BPELEngine tries to call BPELProcess for only
> process in step 3 (newer version) and no entry in correlation table is found
> Instead BPELEngine should iterate over both the versions
--
This message was sent by Atlassian JIRA
(v6.3.4#6332)