Hi Lihua, On 08/26/09 04:09, Zhu Lihua wrote: > Hi Oliver, > Thanks for explanation. > You said "For the new codeline (DEV300) the automation team has the main > goal to stabilize the autotests so that a rerun will not be necessary > anymore." > I wonder how you do that? Just insert delay instruction in script? or > use some new functions in scripts? or make some modification in the > Office side? Because we have to use scripts based on former OOo > milestone, we need modify the scripts we are using to avoid these > issues. > The 3rd problem I mentioned include 2 issues. One is a timing issue. > What do you think of the other one? That is: After tViewToolbars is run, > "Drawing object property" toolbar will not show up in testcase > tFormatPositionAndSizeLegend. IMHO, this is not a right behavior.
tViewToolbars only is opening and closing all available toolbars depending on the defaults. Means default toolbars will remain opened. If later on the Drawing-Toolbar is not opended I would then interprete this as an issue in office application. But currently I can't reproduce this in DEV300m55 build. But...I've seen the warning in tFormatPositionAndSizeLegend some times like you and I wrote an issue for that to add a sleep as you mentioned in wZeichenObjektEinfuegen. Thank you for this valuable hint. With this fix I can't reproduce this warning when running tViewToolbars and tFormatPositionAndSizeLegend afterwards anymore. I will check hToolbarSelect() function if this can cause the toolbar not to be opened. See issue http://qa.openoffice.org/issues/show_bug.cgi?id=104542 for implementation details. Best Regards Helge > > Thank you and best regards, > Lihua > > > > --------------------------------------------------------------------------- > Date: Mon, 24 Aug 2009 11:00:50 +0200 > From: Oliver Craemer - Sun Germany - ham02 - Hamburg <[email protected]> > Content-Type: text/plain; charset=UTF-8; format=flowed > Subject: [qa-dev] [Automation]Problems in OOo3.1.1RC1 zh-CN build > > Hi Lihua, > > all three mentioned problems are known timing problems which occurs > sometimes (often with a bad network / IO performance) and are already > fixed in the current DEV300m55. > For the new codeline (DEV300) the automation team has the main goal to > stabilize the autotests so that a rerun will not be necessary anymore. > > Kind regards, Oliver > > Zhu Lihua wrote: >> Hi all, >> Sun Dequan(sdq) has finished the automation testing of OOo3.1.1RC1. Some >> problems arose. I wonder if they exist in other builds. >> >> Summarize all the problems, we can classify them into 3 types: >> >> >> 1. "Active: UNO URL "Slot:XXXXX" could not be run: Disabled. >> These warnings mainly arise in c_updat2.bas. And they arise randomly in >> testcases if we run the script again. >> Probing into the script showes the problems lie in the following code: >> >> Call hFileOpen(Convertpath(gTesttoolPath + "FileName")) >> Call sMakeReadOnlyDocumentEditable >> >> The first instruction opens a document named "FileName", and the 2nd >> instruction make it editable if it is not. But sometimes the file >> "FileName" is still ReadOnly after the 2 instruction. So, problems >> occur. >> If we insert a "sleep 1" instruction between the instructions, these >> problem will not arise again. >> So, is this a script problem or a performance issue in Chinese build? >> >> 2. "Timeout when waiting the server response" >> These problems often occur in function "hStartTheOffice" and >> "ExitRestartTheOffice" when testing under Windows. Because sometimes >> there is a existing "soffice.bin" process, So Fail to Start Office. >> These problems occurs randomly in many scripts. >> We use the scripts run_test.vbs to start testing. Do you use this >> scripts too? Have you seen these problems? >> >> 3. "Format / Position and Size does not work! Maybe object not >> selected!" >> This problem occurs in tFormatPositionAndSizeLegend in w_updt.bas. Run >> this testcase will not result in the problem. But run the whole script >> will result in the problem. after probing into the script, it turned out >> that the problem caused by another testcase, "tViewToolbars" in >> w_003_.inc. After this testcase, "Drawing object property" toolbar will >> not show when we click callout button in the drawing toolbar. And under >> this condition, the callout may not be selected by wObjektSelektieren. >> Following is the code snippet. >> Call hNewDocument >> Call wZeichenobjektEinfuegen ( "Legende", 45, 35, 50, 50 ) >> printlog " Insert a legend" >> sleep (1) >> Call wObjektSelektieren(43, 33, 75, 75) >> >> There is 2 problems here: >> A. tViewToolbars should not cause the disappearance of the "Drawing >> object property" toolbar. >> B. In function wZeichenobjektEinfuegen(), need a time delay between >> "click the button in toolbar" and "draw the object". Because the 1st >> action may cause the change of the toolbars, if the count of toolbars >> changed, the available area will change accordingly. We need wait until >> the new available area show, since it takes time to hide toolbar and >> resize availble area. To verify this, we add a time delay between the 2 >> actions, and the object can be selected, although the problem A still >> exist. I don't mean this is a solution of the problems, it's just a >> verification for problem B. Problem A disposes problem B. >> This issue also occurs in Japanese build and Russian build, I can see. >> >> Best regards, > > > > -- =============================================================== Sun Microsystems GmbH Helge Delfs Nagelsweg 55 Quality Assurance Engineer 20097 Hamburg OOo Team Lead Automation http://qa.openoffice.org mailto:[email protected] http://wiki.services.openoffice.org/wiki/User:Hde PGP Key-ID: 0x395940C4 --------------------------------------------------------------------- To unsubscribe, e-mail: [email protected] For additional commands, e-mail: [email protected]