Julian Sedding created SLING-4981:
-------------------------------------

             Summary: Deadlock involving Scheduler Whiteboard
                 Key: SLING-4981
                 URL: https://issues.apache.org/jira/browse/SLING-4981
             Project: Sling
          Issue Type: Bug
          Components: Commons
    Affects Versions: Commons Scheduler 2.4.6
            Reporter: Julian Sedding
         Attachments: scheduler-scr-deadlock.log

I repeatedly observed a deadlock situation in an AEM 6.1 installation 
(involving custom code).

The result, amongst others, is a blocked SCR Actor thread.

Hypothesis: I suspect that this can occur in situations where a scheduled Job 
(A) has a reference to another SCR component (B) that is lazily initialized 
(immediate=false) and itself registered via the whiteboard. If A is disabled 
while B is being added by the Scheduler, this triggers deregistration of B as 
well.

[~cziegeler] could you please take a look at the attached thread-dump? I would 
appreciate your opinion on this.




--