Hi Thanuja,

The decision to create different types of data publisher based on
ThriftStatisticsPublisher is good. In that way, we can create own
publishers with different streams as we need. I'm having few concerns on
the factory classes here. Why do we need to have different factory classes
to create datapublsihers? Also in order to just to create one type of data
publisher, do we need to use factory class?

Thanks,
Reka

On Tue, Aug 4, 2015 at 11:01 AM, Thanuja Uruththirakodeeswaran <
thanu...@wso2.com> wrote:

> Hi Devs,
>
> I have started to work on $subject. For the metering service,
>
> 1. I'm going to use three different streams which are member_lifecycle,
> member_info and scaling_decisions as discussed in the review. The streams
> will have attributes as mentioned below:
>
>    - member_lifecycle: time_stamp, member_id, cluster_id,
>    cluster_instance_id, network_partition_id, partition_id, service_name,
>    status
>    - member_info: memberId, hostname, hypervisor, cpu, ram, iaas,
>    imageId, instance_type, login_port, os_name;os_version, is_os_64bit,
>    scaling_id, is_multi_tenant, private_ip, public_ip, allocated_ips
>    - scaling_decision: time_stamp, scaling_id, cluster_id,
>    min_instance_count, max_instance_count, rif_predicted, rif_threshold,
>    rif_required_instances, mc_predicted, mc_threshold, mc_required_instances,
>    la_predicted, la_threshold, la_required_instances, required_instance_count,
>    active_instance_count, additional_instance_count, scaling_reason
>
> 2. Also I'm going to use three publisher classes:
> DASMemberStatusPublisher, DASMemberInformationPublisher and
> DASScalingDecisionPublisher instead of using a single class
> (BAMUsageDataPublisher) as shown below: (Here I've renamed
> WSO2CEPStatisticsPublisher to ThriftStatisticsPublisher)
>
> ​
> 3. Instead of reading uname, pwrod form cloud-controller.xml, I'm going to
> use das-thrift-client-config.xml file and renaming the existing
> thrift-client-config.xml file to cep-thrift-client-config.xml.
>
> Please share your thoughts about this implementation.
>
> Thank you.
> ​​
> --
> Thanuja Uruththirakodeeswaran
> Software Engineer
> WSO2 Inc.;http://wso2.com
> lean.enterprise.middleware
>
> mobile: +94 774363167
>



-- 
Reka Thirunavukkarasu
Senior Software Engineer,
WSO2, Inc.:http://wso2.com,
Mobile: +94776442007

Reply via email to