On 05.08.2016, at 14:18, Richard Eckart de Castilho <[email protected]> wrote: > > Ok, then I think we there is agreement that we keep COMPRESSED_FILTERED (form > 6) > and COMPRESSED_FILTERED_TSI (form 6 + TS).
Hm, I don't see a COMPRESSED_FILTERED_TSI in the SerialFormat. > But for the time being we only support lenient loading (filter on load) - > i.e. the TS in the serialized form corresponds to the original TS from the > CAS. It looks like the following features are currently not supported by CasIOUtils: - storing TS along with form 6 in a single file: I see no code path where a TS is stored in a COMPRESSED_FILTERED binary file and none where it is loaded from a COMPRESSED_FILTERED binary file - lenient loading of COMPRESSED_FILTERED: I do not even see a path where a separately specific TS input stream is used when reading a COMPRESSED_FILTERED file. The TS only seems to be used when reading a SERIALIZED file. Am I missing something? If we still miss the two features listed above, then we kind of lost them in translation. I am pretty sure they were there in the initial code that I provided. Why did we loose them? Cheers, -- Richard