Hi Nirodha, This bug is already reported at [1], and fixed[2] in EI 6.2.0 M3.
[1] https://github.com/wso2/product-ei/issues/835 [2] https://github.com/wso2/carbon-mediation/pull/848 Thanks, Manorama On Wed, Aug 30, 2017 at 10:57 AM, Nirodha Gallage <[email protected]> wrote: > Hi, > > When creating Event Sink config in ESB 4.9.0 and ESB 5.0.0 it supported > giving comma separated multiple Receiver URLs within curly braces, > > Eg: {tcp://192.168.56.168:7611,tcp://192.168.56.159:7611} > > But this is not supported in EI 6.1.1, and does not allow to save the > config with an error "Incomplete URL or Invalid protocol.." > > Isn't it a bug? And is there any workaround for this? > > Regards, > Nirodha > > -- > > *Nirodha Gallage* > Associate Technical Lead > WSO2 Inc.: http://wso2.com/ > Mobile: +94716429078 <+94%2071%20642%209078> > -- Manorama Perera Software Engineer WSO2, Inc.; http://wso2.com/
_______________________________________________ Dev mailing list [email protected] http://wso2.org/cgi-bin/mailman/listinfo/dev