https://issues.apache.org/jira/browse/ZOOKEEPER-2186?page=com.atlassian.jira.plugin.system.issuetabpanels:comment-tabpanel&focusedCommentId=15083051#comment-15083051
 ] 

Markus Aalto commented on ZOOKEEPER-2186:
-----------------------------------------

Any considerations regarding this patch if there is a need to add more 
information into the InitialMessage in future? 
Now with the change it would fail to accept connections from members having 
different protocol version, and I see it will be quite difficult (or 
impossible) to do rolling upgrades in production systems.
 
I'm looking at submitting a feature to implement application level keep alive 
message on the TCP/IP connection used for Leader Election, which would require 
either additional information on the InitialMessage or increasing the protocol 
version. Currently doing either of those would break the compatibility.

> QuorumCnxManager#receiveConnection may crash with random input
> --------------------------------------------------------------
>
>                 Key: ZOOKEEPER-2186
>                 URL: https://issues.apache.org/jira/browse/ZOOKEEPER-2186
>             Project: ZooKeeper
>          Issue Type: Bug
>          Components: server
>    Affects Versions: 3.4.6, 3.5.0
>            Reporter: Raul Gutierrez Segales
>            Assignee: Raul Gutierrez Segales
>             Fix For: 3.4.7, 3.5.1, 3.6.0
>
>         Attachments: ZOOKEEPER-2186-v3.4.patch, ZOOKEEPER-2186.patch, 
> ZOOKEEPER-2186.patch, ZOOKEEPER-2186.patch
>
>
> This will allocate an arbitrarily large byte buffer (and try to read it!):
> {code}
>     public boolean receiveConnection(Socket sock) {
>         Long sid = null;
> ...
>                 sid = din.readLong();
>                 // next comes the #bytes in the remainder of the message      
>                                                                        
>                 int num_remaining_bytes = din.readInt();
>                 byte[] b = new byte[num_remaining_bytes];
>                 // remove the remainder of the message from din               
>                                                                        
>                 int num_read = din.read(b);
> {code}
> This will crash the QuorumCnxManager thread, so the cluster will keep going 
> but future elections might fail to converge (ditto for leaving/joining 
> members). 
> Patch coming up in a bit.



--