Title: RE: [Patch] EMI2 Keepalive patch
The manual says its value is "minute". Are you sure it's seconds? And event it was "seconds" I guess it doesn't get logged to the logs, right?
 
thanks,
Ozkan
-----Original Message-----
From: Andreas Fink [mailto:[EMAIL PROTECTED]]
Sent: Thursday, August 02, 2001 10:14 AM
To: [EMAIL PROTECTED]
Subject: RE: [Patch] EMI2 Keepalive patch

I have two questions for those patches:
 
- I've commented out receive-port from the conf file but the bearerbox didn't start complaining about a missing parameter

That's correct.

- I've added keepalive = 1 to the conf file and set the debugging level to 0. I was expecting to see UCP 31 messages every minute in the logs but there are no such log entrys. Is that normal?
 
Uff, thats ever SECOND, not minute...

-- 

Andreas Fink
Fink-Consulting

------------------------------------------------------------------
Tel: +41-61-6932730 Fax: +41-61-6932729  Mobile: +41-79-2457333
Address: A. Fink, Schwarzwaldallee 16, 4058 Basel, Switzerland
E-Mail:  [EMAIL PROTECTED]  Homepage: http://www.finkconsulting.com
------------------------------------------------------------------
Something urgent? Try http://www.smsrelay.com/  Nickname afink

Reply via email to