Sorry the subject should of course be "TC35".

> -----Original Message-----
> From: Jacob Vennervald Madsen 
> Sent: 1. maj 2002 10:49
> To: [EMAIL PROTECTED]
> Subject: bug in siemens tc53 at2
> 
> 
> Hi List
> 
> I think there is a bug in the Siemens TC35 AT2 code.
> When a message is sent through a Siemens TC35 in PDU mode it can send
> three different responses:
> 
> +CMGS:<mr>OK
> This means that the message was successfully sent.
> 
> OK
> This means that the modem understood the command but it could not send
> the message.
> 
> +CMS ERROR:<err>
> This means that the modem didn't understand the command.
> 
> If I send a lot of messages back and forth on a Siemens modem some
> messages doesn't get sent because kannel takes the OK message as
> successful sending when it really should try sending again.
> 
> Jacob Vennervald
> 
> 

Reply via email to