> -----Messaggio originale-----
> Da: [EMAIL PROTECTED]
> [mailto:[EMAIL PROTECTED]]Per conto di Bruno David Rodrigues
> Inviato: giovedì 18 luglio 2002 18.24
> A: Stefano Baronio
> Cc: devel@kannel
> Oggetto: Re: R: Siemens M35
>
>
> On Thu, 2002-07-11 at 13:29, Stefano Baronio wrote:
> >
> > Stefano Baronio wrote:
> > >
> > > For whoever may be interested I got a Siemens M35i mobile phone (M20
> > family
> > > I think) working with kannel 1.2.
> > > Jus add an init-string in the modems group
> > > init-string = "AT+CNMI=1,2,0,0,1"
> >
> > Sorry, forgot to specify that:
> >
> > 1- at2 driver used.
> > 2- speed must be set to 19200
> >
> > Stefano Baronio
>
> could you send me the ATI result or the modems.conf
> group ?

group = modems
id = siemens_m35i
name = "Siemens M35i"
detect-string = "SIEMENS"
detect-string2 = "M35i"
init-string = "AT+CNMI=1,2,0,0,1"
speed = 19200
need-sleep = true


I just noted that, whilst the M20 works well with GSM numbers without the
'+' (i.e 393281234567 ), the M35 needs the 00 or the + at the begining of
the destination number.


Very rarely happens that kannel sends 3 or 4 messages against 1 http
request. I don't know if it is a kannel or a modem issue by now. In the logs
I can see that it actually sends the messages throught the mobile phone,
with no error messages both from kannel and from the phone.


best regards

Stefano