Nicholas Rahn wrote:
> 
> Attached is a patch implementing the validity period (relative) for
> CIMD2 connections.  It has been tested with one of our swiss CIMD2
> connections.

patch commited to cvs.

> The documentation for the "validity" parameter (sendsms interface) in
> the User's Guide does not mention that this functionality might not be
> implemented for certain SMSC types.  We found that it wasn't implemented
> for CIMD2 only after our clients told us it didn't work.  I'd be willing
> to write an explanation sentence or 2 for the "validity" parameter
> (sendsms interface) of the User's Guide if someone can tell me what
> other SMSCs it works/doesn't work for.

yep, that would be great.

> Question: In this patch, the "algorithm" to convert a time in minutes
> into a integer according to the GSM 03.40 (section 9.2.3.12) spec was
> copied from smsc_at2.c.  Is there a place in kannel where a generic
> function like this could be added rather than copying code?

hmm, that's a good hint. We should have a "shared" file that
incorporates the GSM specific routines?!

Stipe

[EMAIL PROTECTED]
-------------------------------------------------------------------
Wapme Systems AG

Vogelsanger Weg 80
40470 Düsseldorf

Tel: +49-211-74845-0
Fax: +49-211-74845-299

E-Mail: [EMAIL PROTECTED]
Internet: http://www.wapme-systems.de
-------------------------------------------------------------------
wapme.net - wherever you are



Reply via email to