This is a simple true/false test, return bool instead of int.

Signed-off-by: H Hartley Sweeten <[email protected]>
Cc: Ian Abbott <[email protected]>
Cc: Greg Kroah-Hartman <[email protected]>
---
 drivers/staging/comedi/drivers/ni_labpc.c | 15 ++++++---------
 1 file changed, 6 insertions(+), 9 deletions(-)

diff --git a/drivers/staging/comedi/drivers/ni_labpc.c 
b/drivers/staging/comedi/drivers/ni_labpc.c
index f612875..234f85e 100644
--- a/drivers/staging/comedi/drivers/ni_labpc.c
+++ b/drivers/staging/comedi/drivers/ni_labpc.c
@@ -519,16 +519,13 @@ static unsigned int labpc_suggest_transfer_size(const 
struct comedi_cmd *cmd)
 }
 #endif
 
-static int labpc_use_continuous_mode(const struct comedi_cmd *cmd,
-                                    enum scan_mode mode)
+static bool labpc_use_continuous_mode(const struct comedi_cmd *cmd,
+                                     enum scan_mode mode)
 {
-       if (mode == MODE_SINGLE_CHAN)
-               return 1;
-
-       if (cmd->scan_begin_src == TRIG_FOLLOW)
-               return 1;
+       if (mode == MODE_SINGLE_CHAN || cmd->scan_begin_src == TRIG_FOLLOW)
+               return true;
 
-       return 0;
+       return false;
 }
 
 static unsigned int labpc_ai_convert_period(const struct comedi_cmd *cmd,
@@ -1042,7 +1039,7 @@ static int labpc_ai_cmd(struct comedi_device *dev, struct 
comedi_subdevice *s)
                devpriv->cmd4 |= CMD4_ECLKRCV;
        /* XXX should discard first scan when using interval scanning
         * since manual says it is not synced with scan clock */
-       if (labpc_use_continuous_mode(cmd, mode) == 0) {
+       if (!labpc_use_continuous_mode(cmd, mode)) {
                devpriv->cmd4 |= CMD4_INTSCAN;
                if (cmd->scan_begin_src == TRIG_EXT)
                        devpriv->cmd4 |= CMD4_EOIRCV;
-- 
1.8.1.4

_______________________________________________
devel mailing list
[email protected]
http://driverdev.linuxdriverproject.org/mailman/listinfo/devel

Reply via email to