Vladimir Sementsov-Ogievskiy <[email protected]> writes:

> The interface is ambiguous, as "no" is valid file name. So,
> using "no" as a special value to disable script is deprecated.
> Use an empty string ("script=" / "downscript=") instead.
>
> In a future version, "no" will be treated as a plain file name, just
> like any other non-empty value.
>
> Document the deprecation in docs/about/deprecated.rst, qapi/net.json,
> and qemu-options.hx. Update other docs to use empty string instead of
> "no". Add a warning.
>
> Signed-off-by: Vladimir Sementsov-Ogievskiy <[email protected]>

[...]

> diff --git a/net/tap.c b/net/tap.c
> index fedd48c48d2..1ec9e5ebe6f 100644
> --- a/net/tap.c
> +++ b/net/tap.c
> @@ -103,6 +103,8 @@ static bool tap_is_explicit_no_script(const char 
> *script_arg)
>      }
>  
>      if (strcmp(script_arg, "no") == 0) {
> +        warn_report("script=no/downscript=no is deprecated; "
> +                    "use script=/downscript= instead");

net_init_tap() could pass the parameter name for a simpler error
message.  Probably not worth the bother.

>          return true;
>      }
>  

In net_init_tap_one():

           qemu_set_info_str(&s->nc, "ifname=%s,script=%s,downscript=%s", 
ifname,
                             script ?: "no", downscript ?: "no");

This sets nc->info_str, which is shown by "info network".  Should we
replace "no" by ""?

[...]

Reply via email to