FYI the issue was resolved - https://svn.open-mpi.org/trac/ompi/ticket/1376
Regards,
Pasha
Bogdan Costescu wrote:
On Thu, 3 Jul 2008, Pavel Shamis (Pasha) wrote:
I had similar issue recently. It will be nice to have option to
disable/enable *CM via config flags.
Not sure if this is related... I am looking at using a nightly 1.3
snapshot and I get this type of error messages when running:
[n020205][[36506,1],0][connect/btl_openib_connect_ibcm.c:723:ibcm_component_query]
failed to open IB CM device: /dev/infiniband/ucm0
which is actually right, as /dev/infiniband on the nodes doesn't
contain ucm0. On the same cluster, OpenMPI 1.2.7rc2 works fine; the
configure options for building them are the same.
The output of ldd shows for the binary linked with 1.3a:
libibcm.so.1 => /opt/ofed/1.2.5.4/lib64/libibcm.so.1
while this is missing from the binary linked with 1.2. Even after
printing these messages, the binary linked with 1.3a works; it works
even when I specify "--mca btl openib,self" so I think that the IB
stack is still being used (there is also a TCP/GigE network which
could be chosen otherwise).
I don't know whether this is caused by a somehow inconsistent setup of
the system, but I would welcome an option to make 1.3a behave like 1.2.