> Hello Gabriel,
> 
> I get a test failure in spntp01 now using the sparc/gr740 and 
> arm/xilinx_zynq_a9_qemu BSP:
> 
> F:23:0:UI1:init.c:84:2 == 0
> 
> Did you observe this test failure also?
> 
Yes,  thanks for noticing it. It is due the changes in [PATCH v3 09/11]. The 
default value for pps_shift is PPS_FAVG which is equals to 2.