On Fri, Dec 4, 2015 at 4:11 PM, Jehan-Guillaume de Rorthais <[email protected]> wrote:
> > But I fail to understand how I could distinguish, even from notifications, a > failing scenario from a move/switchover one. > On demote fetch current log position and store it in cluster attribute. On promote fetch previous master position, wait until current instance caught up and delete attribute. If attribute is not present on promote, master was down so do not wait and proceed. If you set transient attribute, cluster will forget about previous master on restart. If you set persistent attribute, it will allow you to ensure no data loss has (automatically) occurred even on cluster restart. Where do you envision problems here? _______________________________________________ Developers mailing list [email protected] http://clusterlabs.org/mailman/listinfo/developers