Some timer variants have different mechanisms to clear a pending timer interrupt. Therefore don't hardcode the reading of the eoi register to clear them, but instead use the already existing eoi callback for this.
Signed-off-by: Ulrich Prinz <ulrich.pr...@googlemail.com> --- drivers/clocksource/dw_apb_timer.c | 11 +++++++---- 1 file changed, 7 insertions(+), 4 deletions(-) diff --git a/drivers/clocksource/dw_apb_timer.c b/drivers/clocksource/dw_apb_timer.c index bd45351..5f80a30 100644 --- a/drivers/clocksource/dw_apb_timer.c +++ b/drivers/clocksource/dw_apb_timer.c @@ -121,11 +121,14 @@ static irqreturn_t dw_apb_clockevent_irq(int irq, void *data) return IRQ_HANDLED; } -static void apbt_enable_int(struct dw_apb_timer *timer) +static void apbt_enable_int(struct dw_apb_clock_event_device *dw_ced) { + struct dw_apb_timer *timer = &dw_ced->timer; unsigned long ctrl = apbt_readl(timer, timer->reg_control); + /* clear pending intr */ - apbt_readl(timer, timer->reg_eoi); + if (dw_ced->eoi) + dw_ced->eoi(timer); ctrl &= ~APBTMR_CONTROL_INT; apbt_writel(timer, ctrl, timer->reg_control); } @@ -200,7 +203,7 @@ static void apbt_set_mode(enum clock_event_mode mode, break; case CLOCK_EVT_MODE_RESUME: - apbt_enable_int(timer); + apbt_enable_int(dw_ced); break; } } @@ -325,7 +328,7 @@ void dw_apb_clockevent_register(struct dw_apb_clock_event_device *dw_ced) apbt_writel(timer, 0, timer->reg_control); clockevents_register_device(&dw_ced->ced); - apbt_enable_int(timer); + apbt_enable_int(dw_ced); } /** -- 1.7.10.4 _______________________________________________ devicetree-discuss mailing list devicetree-discuss@lists.ozlabs.org https://lists.ozlabs.org/listinfo/devicetree-discuss