On 17/03/14 16:22, Laurent Pinchart wrote:

>> +Example
>> +-------
>> +
>> +lcd0: display {
>> +    compatible = "tpo,taal", "panel-dsi-cm";
>> +    label = "lcd0";
>> +
>> +    gpios = <&gpio4 6 GPIO_ACTIVE_HIGH>;    /* 102, reset */
> 
> If the panel uses a TE GPIO but no reset GPIO, do you plan to express this 
> with a "hole" for the reset GPIO ? e.g. something like
> 
>       gpios = <0>, <&gpio4 6 GPIO_ACTIVE_HIGH>;

Yes.

> Wouldn't it be better to split the gpios property into "reset-gpios" and "te-
> gpios" ?

Yes, I can change it. I don't have a strong preference.

I've gotten similar comments for other bindings also, so I guess the
preferred way is to use named "-gpios" properties for everything except
the case where you really have multiple gpios with the same purpose?

The gpio binding documentation doesn't give much guidance on this.

 Tomi


Attachment: signature.asc
Description: OpenPGP digital signature

Reply via email to