Trip points corresponding to the one defined in the exynos_tmu_data.c
for Exynos5 have been included.
This thermal-zones attribute is afterwards reused for Exynos5422.

Changes since v1 : Fixed the thernal_sensor registration of the sensors tmu_cpu0

Tested-by: Markus Reichl <m.rei...@fivetechno.de>
Reviewed-by: Lukasz Majewski <l.majew...@samsung.com>
Signed-off-by: Anand Moon <linux.am...@gmail.com>
---
 arch/arm/boot/dts/exynos5-cpu-thermal.dtsi | 59 ++++++++++++++++++++++++++++++
 1 file changed, 59 insertions(+)
 create mode 100644 arch/arm/boot/dts/exynos5-cpu-thermal.dtsi

diff --git a/arch/arm/boot/dts/exynos5-cpu-thermal.dtsi 
b/arch/arm/boot/dts/exynos5-cpu-thermal.dtsi
new file mode 100644
index 0000000..3ce8872
--- /dev/null
+++ b/arch/arm/boot/dts/exynos5-cpu-thermal.dtsi
@@ -0,0 +1,59 @@
+/*
+ * Device tree sources for Exynos5 thermal zone
+ *
+ * Copyright (c) 2015 Lukasz Majewski <l.majew...@samsung.com>
+ *                     Anand Moon <linux.am...@gmail.com>
+ *
+ * This program is free software; you can redistribute it and/or modify
+ * it under the terms of the GNU General Public License version 2 as
+ * published by the Free Software Foundation.
+ *
+ */
+
+#include <dt-bindings/thermal/thermal.h>
+
+/ {
+       thermal-zones {
+               cpu0_thermal: cpu0-thermal {
+                       thermal-sensors = <&tmu_cpu0 0>;
+                       polling-delay-passive = <0>;
+                       polling-delay = <0>;
+                       trips {
+                               cpu_alert0: cpu-alert-0 {
+                                       temperature = <50000>; /* millicelsius 
*/
+                                       hysteresis = <5000>; /* millicelsius */
+                                       type = "active";
+                               };
+                               cpu_alert1: cpu-alert-1 {
+                                       temperature = <60000>; /* millicelsius 
*/
+                                       hysteresis = <5000>; /* millicelsius */
+                                       type = "active";
+                               };
+                               cpu_alert2: cpu-alert-2 {
+                                       temperature = <70000>; /* millicelsius 
*/
+                                       hysteresis = <5000>; /* millicelsius */
+                                       type = "active";
+                               };
+                               cpu_crit0: cpu-crit-0 {
+                                       temperature = <100000>; /* millicelsius 
*/
+                                       hysteresis = <0>; /* millicelsius */
+                                       type = "critical";
+                               };
+                       };
+                       cooling-maps {
+                               map0 {
+                                    trip = <&cpu_alert0>;
+                                    cooling-device = <&fan0 0 1>;
+                               };
+                               map1 {
+                                    trip = <&cpu_alert1>;
+                                    cooling-device = <&fan0 1 2>;
+                               };
+                               map2 {
+                                    trip = <&cpu_alert2>;
+                                    cooling-device = <&fan0 2 3>;
+                               };
+                       };
+               };
+       };
+};
-- 
1.9.1

--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to