On Tue, Jul 28, 2015 at 10:08:28PM -0700, Greg KH wrote:
> On Wed, Jul 29, 2015 at 10:42:06AM +0800, Peter Chen wrote:
> > The system bus and chipidea IP have different limitations for
> > both host and device mode.
> > For example, with below errata, we need to enable SDIS(Stream Disable Mode)
> > at host mode. But we don't want it for device mode at the same system.
> > 
> > TAR 9000378958
> > Title: Non-Double Word Aligned Buffer Address Sometimes Causes Host to Hang 
> > on OUT Retry
> > Impacted Configuration: Host mode, all transfer types
> > Description:
> > The host core operating in streaming mode may under run while sending the 
> > data packet of an OUT transaction. This under run can occur if there are 
> > unexpected system delays in fetching the remaining packet data from memory. 
> > The host forces a bad CRC on the packet, the device detects the error and 
> > discards the packet. The host then retries a Bulk, Interrupt, or Control 
> > transfer if an under run occurs according to the USB specification.
> 
> <snip>
> 
> Properly format this huge wall of text please, don't commit this as-is.
> 

Thanks, I will

-- 

Best Regards,
Peter Chen
--