On Wednesday 12 August 2015 07:57 PM, Paul Walmsley wrote:
On Mon, 10 Aug 2015, Keerthy wrote:

Switch to external clock source during suspend and switch back
to internal source on resume. This helps rtc ticking across suspend.

Doesn't this type of dynamic switching make it likely that ticks will be
lost?

If the external, optional source is present, isn't it best just to use the
external source 100% of the time?


Paul,

The intent here is to switch to a higher precision clock which is the internal clock when available.

Alexandre,

Is dynamic switching preferred over sticking to external clock always if present?

Regards,
Keerthy


- Paul

--
To unsubscribe from this list: send the line "unsubscribe devicetree" in
the body of a message to majord...@vger.kernel.org
More majordomo info at  http://vger.kernel.org/majordomo-info.html

Reply via email to