Hi,

On Fri, Sep 25, 2015 at 10:54:06AM -0500, Andreas Dannenberg wrote:
> Extend the bq24257 charger's device tree documentation to cover the
> bq24250 and bq24251 devices as well feature additions.
>
> [...]
>
> +- ti,current-limit: The maximum current to be drawn from the charger's input
> +    (in uA). If this property is not specified a USB D+/D- signal based 
> charger
> +    type detection is used (if available) and the input limit current is set
> +    accordingly. If the D+/D- based detection is not available on a given 
> device
> +    a default of 500,000 is used (=500mA).

I think this wording is a bit better:

- ti,current-limit: The maximum current to be drawn from the charger's input
    (in uA). If this property is not specified, the input limit current is
    set automatically using USB D+/D- signal based charger type detection.
    If the hardware does not support the D+/D- based detection, a default
    of 500,000 is used (=500mA) instead.

-- Sebastian

Attachment: signature.asc
Description: PGP signature

Reply via email to