On Mon, Nov 28 2016 at  4:39pm -0500,
Mike Snitzer <snit...@redhat.com> wrote:

> On Thu, Nov 24 2016 at  2:11am -0500,
> tang.jun...@zte.com.cn <tang.jun...@zte.com.cn> wrote:
> 
> > From: "tang.junhui" <tang.jun...@zte.com.cn>
> > 
> > Hardware handle would be retained no matter parameter
> > retain_attached_hw_handler is set or not in the logic
> > of current code. So remove this useless parameter.
> 
> Right, that wasn't always the case.  Previously (before commit )
> dm-mpath would first detach the attached handler.

meant to reference commit 1bab0de02 ("dm-mpath, scsi_dh: don't let dm
detach device handlers")

--
dm-devel mailing list
dm-devel@redhat.com
https://www.redhat.com/mailman/listinfo/dm-devel

Reply via email to