Hi Elias !
crm status will tell you on which node a given resource is active. You can also use crm_mon (underscore!) which will present the same thing in real time (crm status is a one shot run). Basically, crm is the command to use to do everything you intend to do. Regarding the iSCSI target daemon, you have declared an IP resource in your cluster, the one that your remote iSCSI initiators point to. Since the IP resource is a resource, you will see it in the crm status report, and you will know which node owns it. In order to failover your resources, guess what, you may use crm too! J As far as I remember, its something like crm resource migrate <res_name> <target_host>. Have a look to the crm man pages for more details. You may also manually modify the cib config within the cluster to change the scores of your resources. This is what I use to do, although Im not sure it is actually a best practice To make short, the score is sort of a weight that you give to your resource on a given host. The host on which the weight/score is the highest is the host on which the resource is tied to. Change the scores, the resource moves. You must read at least 2 docs to better understand that complex stuff : 1) Pacemaker 1.0 Configuration Explained, by Andrew Beekhof. There might be a more recent release, but I dont know of it I had to read it twice, but it gives valuable information regarding the way a Pacemaker cluster is structured and works. This manual worths gold! 2) And then the CRM CLI guide (not sure which version is the latest, I have the 0.94) by Dejan Muhamedagic and Yan Gao, to understand all crm is able to achieve, and thats not few! Also, the Cluster from scratch manual is a good introduction. An dit contains DRBD examples. May be you might start by it, to catch the first concepts It is easier to read than the Pacemaker 1.0 Configuration Explained I mentioned above. Youll find all this on the web of course! HTH! Best regards, Pascal. De : drbd-user-boun...@lists.linbit.com [mailto:drbd-user-boun...@lists.linbit.com] De la part de Elias Chatzigeorgiou Envoyé : jeudi 5 janvier 2012 03:14 À : drbd-user@lists.linbit.com Objet : [DRBD-user] HA DRBD setup - graceful failover/active node detection I have a two-node active/passive cluster, with DRBD controlled by corosync/pacemaker. All storage is based on LVM. ---------------------------------------------------------------------------- -------- a) How do I know, which node of the cluster is currently active? How can I check if a node is currently in use by the iSCSI-target daemon? I can try to deactivate a volume group using: [root@node1 ~]# vgchange -an data Can't deactivate volume group "data" with 3 open logical volume(s) In which case, if I get a message like the above then I know that node1 is the active node, but is there a better (non-intrusive) way to check? A better option seems to be 'pvs -v'. If the node is active then it shows the volume names: [root@node1 ~]# pvs -v Scanning for physical volume names PV VG Fmt Attr PSize PFree DevSize PV UUID /dev/drbd1 data lvm2 a- 109.99g 0 110.00g c40m9K-tNk8-vTVz-tKix-UGyu-gYXa-gnKYoJ /dev/drbd2 tempdb lvm2 a- 58.00g 0 58.00g 4CTq7I-yxAy-TZbY-TFxa-3alW-f97X-UDlGNP /dev/drbd3 distrib lvm2 a- 99.99g 0 100.00g l0DqWG-dR7s-XD2M-3Oek-bAft-d981-UuLReC where on the inactive node it gives errors: [root@node2 ~]# pvs -v Scanning for physical volume names /dev/drbd0: open failed: Wrong medium type /dev/drbd1: open failed: Wrong medium type Any further ideas/comments/suggestions? ---------------------------------------------------------------------------- -------- b) how can I gracefully failover to the other node ? Up to now, the only way I know is forcing the active node to reboot (by entering two subsequent 'reboot' commands). This however breaks the DRBD synchronization, and I need to use a fix-split-brain procedure to bring back the DRBD in sync. On the other hand, if I try to stop the corosync service on the active node, the command takes forever! I understand that the suggested procedure should be to disconnect all clients from the active node and then stop services, is it a better approach to shut down the public network interface before stopping the corosync service (in order to forcibly close client connections)? Thanks
_______________________________________________ drbd-user mailing list drbd-user@lists.linbit.com http://lists.linbit.com/mailman/listinfo/drbd-user