Good day,
When adding the following command with the --common (global_common config)
parameters for auto split-brain recovery:
drbdmanage net-options --common --after-sb-0pri
discard-zero-changes --after-sb-1pri discard-secondary --after-sb-2pri
disconnect
We get the following error in the syslog when it detects split brain on
"after-sb-0pri":
kernel: [20366.748081] drbd vm-100-disk-1 pve1: incompatible after-sb-0pri
settings
If we instead set the option on the resource vm-100-disk-1:
drbdmanage net-options --resource vm-100-disk-1
--after-sb-0pri discard-zero-changes --after-sb-1pri discard-secondary
--after-sb-2pri disconnect
It is now working and we get no error messages in syslog.
DRBD version:
root@pve1:~# dpkg -l | grep drbd
drbd-utils 8.9.6-1
amd64 RAID 1 over TCP/IP for Linux (user utilities)
drbdmanage 0.96-1 amd64
Distributed configuration management for DRBD
We are running Proxmox VE 4.2 with the latest updates.
Can this be a bug on how the command gets translated from the global_common
config?
Regards,
Urban
_______________________________________________
drbd-user mailing list
[email protected]
http://lists.linbit.com/mailman/listinfo/drbd-user