Hi,

 

I don't know if this is the right forum, but I think it's driver
related.

 

I use mpt_sas driver to connect my front-bay SAS disks, mpt_sas is
configured to use MPxIO.

 

If I pull out a faulty zpool disk, I always have a "drive type unknown "
entry in the output of "format" ,

Putting a new disk into the same SAS bay does not remove that entry.

 

       0. c1t5000C50028C8B377d0 <SEAGATE-ST3600057SS-0006-558.91GB>

          /scsi_vhci/disk@g5000c50028c8b377

       1. c1t5000C50028C89B5Bd0 <drive type unknown>

          /scsi_vhci/disk@g5000c50028c89b5b

 

The only way to get rid of this entry is to put the same disk  back,  or
maybe reboot can get rid of this entry, but I haven't tried.

 

However, if I pull out a disk that does not belong to a zpool, I don't
have this entry in "format".

 

I understand that each SAS disk has its own GUID, and when MPxIO is
enabled,  Solaris uses

That GUID as part of the OS path, that explains why putting a new disk
into the bay does not remove the old entry,

But why removing a disk leaves a entry in format,  shouldn't devfsadm
remove that path ?

 

Is this a known issue for SAS disk?  or Did I miss anything
configuration-wise ?

 

How can I remove this entry without reboot ?

 

 

Thanks

 

Tianhong Zhao | Senior Systems Architect
p. +1.514.683.1020 x145

[email protected]

www.nexsan.com <http://www.nexsan.com/> 

 

This message is confidential and may also be legally privileged. It is
intended for the use of the individual to whom it is addressed. 

If you are not the intended recipient, please notify the sender via
email and delete the message and you should not copy it or use 

it for any purpose, nor disclose its contents to any other person. Thank
you. 

 