Weeks ago I described my trouble with DX4Win freezing up or pausing when 
using my new FT-950. With a lot of research I found out it was a problem 
with the FT950.RIG file.

I found that the ft950.rig file had some errors that told the computer 
to pause and wait. Specifically, the "CDELAY=260" value should have had 
been "CDELAY=0" on the [RC-Read xxxx ] heading items, like [RC-Read 
Mode], [RC-Read S Meter], [RC-Read Status], etc.....

Other Yaesu .rig files had "CDELAY=0" for the READ functions while the 
supplied FT-950 file had a value of CDELAY=260.

Once I changed these values to zero, the delay & hang ups stopped. I 
checked the rig control functions as much as I could and did not find 
any problems caused by this change.

Now after I made the changes, there isn't any delay hang up or pause in 
the CW keying or program operation.

If anyone has a FT-950 and wants a copy of my file, please let me know 
and I will email it to you direct.

Ernie W8EH