Hello!

I have two servers. One with Intel 82576 Gigabit NIC and second with Intel 
Corporation 82599EB 10-Gigabit NIC installed.
Both servers connected to Cisco 3750X switch. Flow control is disabled by 
default on all switch ports.

There were Discards In on a second server (82599EB, ixgbe). But after manually 
disabling Flow control they are gone.

As shown below igb driver disable Flow Control but ixgbe does not disable Flow 
Control

Intel 82576 Gigabit NIC

# ethtool -i eth0
driver: igb
version: 2.1.0-k2
firmware-version: 1.4-3

# ethtool -a eth0
Pause parameters for eth0:
Autonegotiate:  on
RX:             on
TX:             off


Intel Corporation 82599EB 10-Gigabit NIC

# ethtool -i eth4
driver: ixgbe
version: 3.7.14-NAPI
firmware-version: 0x18f10001

# ethtool -a eth4 
Pause parameters for eth4:
Autonegotiate:  on
RX:             on
TX:             on


Best regards,
Aleksey


------------------------------------------------------------------------------