Hi all,
we are testing the eagle-2.3.1 for the eagle-II modem on our PPC 
embedded system. During the test, that just send the ping to 
another system via adsl, we have had a lot of warning:
"eu_uni_process_in_data: non-integral number of cells in incoming 
data"
"eu_uni_process_in_data: incoming data length = 3f."
"eu_uni_process_in_data: ATM_CELL_SIZE = 35."
.....
so we lost a frame every time we have this warning, and some times 
our usb controller got also the "STALL" from the modem. 

We are using USB_BULK mode to receive the data, instead of 
isochronous mode to simplify the things.

I think that the firmware of the modem has some problems to 
assemble the eth packets, but our usb driver has also some 
problems that put the modem in stall on control mode, that take 
the handshake between usb controller and the modem. We are 
debugging it.

I've also sent a patch about ppc to eagle-usb forum and I don't 
know if you have acepted it.

Thanks in advance for any suggestion.

Jianliang Lu


                   

Reply via email to