Hi,

CMV implementation is committed in CVS and remains to be tested :
- CMVepWO.txt is currently the default for all ISP (to be changed)
- Linetype is not (yet) changed : to be edited to Linetype=0000000A in
/etc/eagle-usb/eagle-usb.conf
- some CMVep{ISP}.txt files have to be created
- we'll have to distinguish ISDN from POTS (as long as the DSPcode does
not manage CMV for ISDN) : the difficulty is that we do not know if
eaglectrl can re-send CMV values (to erase previous ones) and if an
interactive mode can be implemented, all questions at :
http://dev.eagle-usb.org/wakka.php?wiki=DevEagleUsbIII (If Analog can have
a look at paragraph "questions" : there's questions/answers too when some
answers are available).

Ludovic and all, can you test again ? (take new version from CVS). We'll
try to make a release candidate (tar.bz2) for next week so that it can be
implemented in Mandrakelinux 10.2 (hopefully). At least, we'll get it to
work with Sagem Fast 800 E3...

BTW, we have users that still have problems with Cegetel ADSL Max :
http://forum.eagle-usb.org/viewtopic.php?p=18878
now it is OPTN 5 which seems to be a problem and keeps the modem
"INITIALIZING" if not put to 0 (instead of 500) with a Sagem Fast 800 E2L
with latest BNM, what is it used for ?
So far, we've understood only what is compiled here :
http://faq.eagle-usb.org/wakka.php?wiki=InfoCMVEn

@++
Ben'. aka baud123


Reply via email to