----- Original Message ----- 
From: "Benoît Audouard" <[EMAIL PROTECTED]>
To: <[email protected]>
Cc: <[EMAIL PROTECTED]>; <[EMAIL PROTECTED]>;
<[EMAIL PROTECTED]>; <[EMAIL PROTECTED]>
Sent: Monday, October 25, 2004 6:04 PM
Subject: [Eagleusb-dev] Re: Réf. : RE: EagleIII : tests report


> Hi,
> I send this on our public ML, with Analog / Sagem in BCC (so you can
choose to
> answer privately or publicly)
> > Dear all,
> >
> > ADI released an update of the BNM code. This new code "44e2ea17"
> > should be used instead of "44e2ea16". This new code is compatible
> > with any hardware version of Eagle chipset.
> >
> > (See attached file: RTBLD_44e2ea17.BNM)
> ok I may have time to look at this, this evening. I'll put online a new
> version with these BNM included. I hope some more testing can be done with
> current BNM, to be sure that Oops are eradicated.
>
> > This code should be used in conjunction with the following CMVs.
> >
> > (See attached file: CMVep_Spain.txt)(See attached file:
> > CMVep_other.txt)
> > (See attached file: CMVep_Italy.txt)
> Hence a proposal I made before :
> - wouldn't it be better to have a directive FILEPOTS / FILEISDN in
> /etc/eagle-usb/eagle-usb.org to indicate which CMV file to use ?
> - or eagleconfig can make a symbolic link on the appropriate file (that
could
> be put in /usr/share/eagle-usb... well to be defined to be compliant with
LSB,
> I'm not the specialist in this area)
>
Is /etc/eagle-usb/eagle-usb.org a new file ? :-)
You don't need one but two links, one for POTS, the other for ISDN as the
modem it-self select the proper file.

I would prefer one new directive wich contain an optional termination.
CMVCountry could be at this time '','FR','IT','SP' but can be extended
without compilation of the driver.
So the driver will be able to select CMVepFR.txt or CMVeiFR.txt,
CMVepIT.txt... or a basic CMVep.txt where the non-TR48 CMV will be.

> And several questions :
> - in Spain there are at least two kinds of ISP :
>  - Telefonica based : using IPoA (RFC 1483 bridge LLCsnap) or PPPoE LLC
(RFC2516)
>  - "Wanadoo/Eresmas" based : same configuration as in France (PPPoA VCmux)
>  => do those CMV work for both ?
> - does it exist a "default configuration" that works in every country /
for
> every ISP ?

In the windows driver installation (setup.ini), there is :
;Auto Config flag:
;0: AC disabled
;1: AC trial version enabled
;2: AC TR37 enabled
AutoConfig=0

TR37 is Network Management & Operations: DSL CPE Auto-Configuration
I don't how much it is reliable.

> - how will be informed of appropriate configuration when today it's
already
> very difficult to obtain VPI / VCI / Encapsulation for every ISP... Is it
> depending only on the country or the ISP ?
> - I'm not yet convinced of an existing "default configuration" as OPTN1
has
> already caused problems of download rate divided by 10 (we have to guess
from
> experience)
>

AVM modemmaker use a drdsl binary to set automaticly the proper settings in
an adsl.conf file.

But for ATM settings selection, it's look not to be automaticly set in most
cases.

Gilles