Hi Experts,

 

In ParseEdidData() in
IntelFrameworkModulePkg\Csm\BiosThunk\VideoDxe\BiosVideo.c, the EDID
information pointed by EdidBuffer is in the format of VBE 3.0 and retrieved
by int 10 4F15. According to the definition of following timing fields,
1280*1024 should be the highest resolution to be supported in this way.

 

EstablishedTimings[0]:

Bitfields for DPMS established timings 1:

Bit(s)         Description      

0     720x400 @ 70 Hz (VGA 640x400, IBM)

1     720x400 @ 88 Hz (XGA2)

2     640x480 @ 60 Hz (VGA)

3     640x480 @ 67 Hz (Mac II, Apple)

4     640x480 @ 72 Hz (VESA)

5     640x480 @ 75 Hz (VESA)

6     800x600 @ 56 Hz (VESA)

7     800x600 @ 60 Hz (VESA)

 

EstablishedTimings[1]:

Bitfields for DPMS established timings 2:

Bit(s)         Description      

0     800x600 @ 72 Hz (VESA)

1     800x600 @ 75 Hz (VESA)

2     832x624 @ 75 Hz (Mac II)

3     1024x768 @ 87 Hz interlaced (8514A)

4     1024x768 @ 60 Hz (VESA)

5     1024x768 @ 70 Hz (VESA)

6     1024x768 @ 75 Hz (VESA)

7     1280x1024 @ 75 Hz (VESA)

 

Our question is if there is one way to retrieve the information about higher
resolution, if it's supported by video output device?

 

 

Thanks,

Hawk.

------------------------------------------------------------------------------