Reflector Members,

Instructions say :

Measure the TP2 near L1 in the upper left corner of the RF board.  This is the 
low-noise amplifier (LNA) bias level.  Adjust R13 for between 200 and 275 mV 
(250 mV nominal).



All I can get from R13 fully clockwise is 245 mV.  Will this present a problem 
being at the "fully clockwise" position and being under the rating that is 
considered the "nominal" setting?  This is an identical reading for two 
separate transverters.

Paul
K8QT
K2/100 #3479